xStack
®
DES-3810 Series Layer 3 Managed Ethernet Switch Web UI Reference Guide
126
Figure 5-68 MLD Snooping Settings window
The fields that can be configured are described below:
Parameter
Description
MLD Snooping State
Here the user can enable or disable the MLD snooping state.
Max Learning Entry Value
(1-1024)
Here the user can enter the maximum learning entry value.
Click the
Apply
button to accept the changes made for each individual section.
Click the
Modify Router Port
link to configure the MLD Snooping Router Port Settings for a specific entry.
Click the
Edit
button to configure the MLD Snooping Parameters Settings for a specific entry.
Enter a page number and click the
Go
button to navigate to a specific page when multiple pages exist.
After clicking the
Edit
button, the following page will appear:
Figure 5-69 MLD Snooping Parameters Settings window
The fields that can be configured are described below:
Parameter
Description
Query Interval (1-65535)
Specifies the amount of time in seconds between general query transmissions. The
default setting is 125 seconds.
Max Response Time (1-
25)
The maximum time in seconds to wait for reports from listeners. The default setting is
10 seconds.
Robustness Value (1-7)
Provides fine-tuning to allow for expected packet loss on a subnet. The value of the
robustness variable is used in calculating the following MLD message intervals:
•
Group listener interval
- Amount of time that must pass before a multicast router
decides there are no more listeners of a group on a network. This interval is
calculated as follows: (robustness variable x query interval) + (1 x query
response interval). The default value is 260 seconds.
•
Other Querier present interval
- Amount of time that must pass before a
multicast router decides that there is no longer another multicast router that is
the Querier. This interval is calculated as follows: (robustness variable x query
interval) + (0.5 x query response interval). The default is 255 seconds.