Chapter 3
:
Installation
42
SE505 Hardware Manual
Figure 38.
Electrical Wiring
5. Connect L (brown) and N (blue) to the connections marked on the lower face of the circuit
breaker.
6. Connect the ground wire to one of the green terminals on the terminal block:
a.
Insert a screwdriver to release the crimp-style connector.
b.
Insert the stripped portion of the wire into the connector.
c.
Remove the screwdriver, allowing the connector to crimp the conductor.
d.
Pull the wire to ensure it is secured.
7. Replace the power access cover and secure with four screws.
Pry open the crimping connector using a
screwdriver and insert the conductor.
Screwdriver
Stripped wire
NOTE: The SE505 does not comes with power cord.
PE
PE
PE
N2
L2
PE
N1
L1
N
L
N (blue)
L (brown)
GND (yellow)
Power Cord
(AWG 14–16)
Caution:
If the ground is not properly connected, the entire machine chassis will float at half
the supply voltage.
Содержание SE505
Страница 1: ...SE505 Hardware Manual ...
Страница 6: ...Contents vi SE505 Hardware Manual ...
Страница 10: ...x SE505 Hardware Manual ...
Страница 11: ...CyberOptics Corporation 1 Safety Safety Guidelines 2 Compliance 7 Safety and Conformity Labeling 8 ...
Страница 72: ...Chapter 3 Installation 62 SE505 Hardware Manual ...
Страница 168: ...Chapter 4 Replacing Components and Preventive Maintenance 158 SE505 Hardware Manual ...
Страница 180: ...Index 170 SE505 Hardware Manual ...