CyberOptics Corporation
121
Conveyor Components
7. Turn the 7 mm spanner counter clockwise to unlock the lock nut.
8. Detach the cylinder and the centre lifter plate completely with the 7 mm spanner. Turn in a
clockwise direction.
9. Use Allen key No. 2.5 to release the cylinder from the cylinder plate. Remove the cylinder
and replace with a new cylinder.
10. Reverse the process to reassemble.
Lock nut
i
Note:
For more information on system alignment, refer to “
Aligning the System”
section of the
“SE505 Solder Paste Inspection Software User Guide, Part Number: 8015918.