CyberOptics Corporation
97
Processor Components
➢
To clean the processor’s air filter
1. Turn off all electrical power to the system. For more information, refer to the section
2. Open the hood on the SE505.
3. Make sure all motion has stopped.
4. Remove two screws that secure the lower front panel to the machine frame.
5. Lift the air filter up and out from the front of the processor.
Figure 58.
Processor Air Filter
6. Using clean, dry, compressed air to remove the dust buildup from the air filter. Keep away
from the system so the dust will not be blown into the electronics panel.
7. Replace the air filter in the front of the processor.
8. Replace the lower font panel.
9. Close the SE505 hood.
Warning:
Make sure the AC main circuit breaker is turned OFF and power is disconnected
from the mains before starting on any procedure.
Air Filter
Содержание SE505
Страница 1: ...SE505 Hardware Manual ...
Страница 6: ...Contents vi SE505 Hardware Manual ...
Страница 10: ...x SE505 Hardware Manual ...
Страница 11: ...CyberOptics Corporation 1 Safety Safety Guidelines 2 Compliance 7 Safety and Conformity Labeling 8 ...
Страница 72: ...Chapter 3 Installation 62 SE505 Hardware Manual ...
Страница 168: ...Chapter 4 Replacing Components and Preventive Maintenance 158 SE505 Hardware Manual ...
Страница 180: ...Index 170 SE505 Hardware Manual ...