Gantry Components
Adjusting the Encoder Read Head
This procedure is needed to perform when a required 0.8 mm air gap between the read head
and the scale is lost during a collision with obstacles in the application or when the replacement
of the encoder head is done.
This procedure can be performed with access to the left/right of the machine in production line.
This section shows the procedure performed when the machine is not in production line.
➢
To adjust the encoder read head
1. Turn off all electrical power to the system. For more information, refer to the section
2. Open the SE505 hood.
3. Make sure all motion has stopped.
4. Locate the encoders to be replaced on the X-axis and Y-axis.
5. Loosen the two screws as shown in Figure 108.
Figure 108.
Encoder carrier screws
6. Insert a RENISHAW 0.8 mm spacer between the read head and the scale. Contact
CyberOptics for the part number of the REINSHAW spacer.
7. Slightly press the read head with finger to clamp the spacer and tighten the screws.
8. Move the carrier aside slowly and remove the spacer.
i
Note:
The required 0.8 mm air gap must be maintained in order for the encoder to deliver
accurate position feedback and to enable the stage to position accurately.
Screw
Screw
REINSHAW
0.8mm Spacer
Caution:
Do not scratch the scale.
Содержание SE505
Страница 1: ...SE505 Hardware Manual ...
Страница 6: ...Contents vi SE505 Hardware Manual ...
Страница 10: ...x SE505 Hardware Manual ...
Страница 11: ...CyberOptics Corporation 1 Safety Safety Guidelines 2 Compliance 7 Safety and Conformity Labeling 8 ...
Страница 72: ...Chapter 3 Installation 62 SE505 Hardware Manual ...
Страница 168: ...Chapter 4 Replacing Components and Preventive Maintenance 158 SE505 Hardware Manual ...
Страница 180: ...Index 170 SE505 Hardware Manual ...