CyberOptics Corporation
101
Conveyor Components
Replacing the Conveyor Clamp Blade
Use this procedure to replace the clamp blade on the front or back conveyor rail. This procedure
can be performed with access to the left/right of the machine in production line.This section
shows the procedure performed when the machine is not in production line.
Parts
Conveyor Blade
Required Tools
–
No. 4 Allen Key
–
Ball Pein Hammer
–
Threadlock Sealant (Loctite No. 2163 or equivalent)
➢
To replace the conveyor clamp blade
1. Turn off all electrical power to the system. For more information, refer to the section
2. Remove all the M4 screws on the top of the blade holder.
Figure 63.
Blade Holder and clamp blade
3. Remove and replace the old clamp blade with a new one.
4. Measure the distance gap between the top guide and the clamp blade. Repeat for the other
end.
Figure 64.
Top Guide Gap
i
Note:
For Parts Replacement, contact CyberOptics for part numbers.