7. Remove all the five M5 nuts on the top of the edge guide.
Figure 46.
Screws on top of edge guide
8. Replace with a new edge guide.
9. Replace the five M5 nuts and spring.
10. Replace the two screws located at the blade holder using Allen key No. 2.5.
11. Turn the right-hand lock plate at the front clamp assembly in a counter clockwise direction.
Turn the left-hand lock plate in a clockwise direction.
12. Apply threadlocking to the screws after unlocking to ensure the rigidity of the clamp
assembly.
13. Using steps 10–11 of the procedure for replacing the conveyor belt. Refer to the section
➢
To replace the edge guide at rear clamp assembly
1. Remove the five screws on the edge guide.
2. Replace with a new edge guide.
3. Use steps 9–13 to reassemble the top clamp.