CyberOptics Corporation
149
Other Components
7. Remove two screws at the top and remove the safety interlock switch.
8. Loosely attach the new safety interlock switch onto the bracket with two screws.
9. Re-insert the cable through the strain-relief nut.
10. Reconnect six wires. Refer to the color coding table in Figure 97.
11. Install the cover onto the safety interlock switch.
Figure 97.
Safety Interlock Switch
➢
To align safety interlock switch
1. Press the green ON button to turn on system power.
2. Close the hood to make sure the pin is lined up with the safety interlock switch socket. To
check the alignment:
●
Re-engage the E-Stop.
●
Observe the safety circuit relays inside the electronics panel. The LEDs should be turned
on.
3. Adjust the switch for correct alignment and tighten the mounting screws.
Black
Brown
White
Green
Blue
Red
Color
Signal
Black
Safety relay coil
White
Safety relay coil
Red
Safety relay coil
Green
Ground
Brown
+24V pilot
Blue
Interlock signal