Chapter 3
:
Replacing Components and Preventive Maintenance
130
SE500
ULTRA
Hardware Manual
Replacing the X-Axis
Use this procedure to replace the X-Axis on the gantry. This section shows the procedures
performed when the machine is not in the production line.
Parts
X-Axis
➢
To replace the X-Axis of the gantry
1. Turn off all electrical power to the system. For more information, refer to the section
2. Remove the screws attached to the grounding board.
3. Remove the screws attached on the base of the cable chain and cable chain bracket.
4. Remove the D-Sub connectors.
i
Note:
For Parts Replacement, contact CyberOptics for part numbers.
screw
screw
screw
screws
base
Содержание SE500ULTRA
Страница 1: ...SE500ULTRA Hardware Manual ...
Страница 6: ...Contents vi SE500ULTRA Hardware Manual ...
Страница 10: ...x SE500ULTRA Hardware Manual This page is intentionally left blank ...
Страница 28: ...Chapter 1 System Overview 18 SE500ULTRA Hardware Manual Dimensions Figure 8 Front View ...
Страница 30: ...Chapter 1 System Overview 20 SE500ULTRA Hardware Manual ...
Страница 163: ...CyberOptics Corporation 153 AC and DC Distribution Block Diagram AC and DC Distribution Block Diagram ...
Страница 184: ...Chapter 5 System Drawings 174 CyberOptics Corporation ...