Chapter 3
:
Replacing Components and Preventive Maintenance
92
SE500
ULTRA
Hardware Manual
➢
To clean the processor’s air filter
1. Turn off all electrical power to the system. For more information, refer to the section
2. Open the hood on the SE500
ULTRA
.
3. Make sure all motion has stopped.
4. Remove two screws that secure the lower front panel to the machine frame.
5. Lift the air filter up and out from the front of the processor.
Figure 42.
Processor Air Filter
6. Using clean, dry, compressed air to remove the dust buildup from the air filter. Keep away
from the system so the dust will not be blown into the electronics panel.
7. Replace the air filter in the front of the processor.
8. Replace the lower font panel.
9. Close the SE500
ULTRA
hood.
Warning:
Make sure the AC main circuit breaker is turned OFF and power is disconnected
from the mains before starting on any procedure.
Air Filter
Lift up