69
12. Multi-step function mode ■
◆Multi-step function mode reset
Description: Memorized of current operation step and time (in sec) while shut down or power failure.
Step and time reset to 0 when set CE48=1.
Notice: External terminal 6 set to RST function, when RST connect with COM, it will reset the records
and steps time to 0.
◆Multi-step function mode selecting
Constant
No.
Constant name
Settable range
Factory setting
Change during
operation
CE47
Multi-step function mode selecting
0 6
0
X
Description: Select operation modes on speed variation when process control switch from previous
stepto next step.
0: Liner operation, stop after operated one circle.
1: Liner operation, automatical restart fro first circle after operated one circle.
2: Liner operation, stay at last step after operated one circle and wait for input signal of reset,
restart from first circle.
3: Reserved.
4: Gradually operation, stop after operated one circle.
5: Gradually operation, automatical restart fro first circle after operated one circle.
6: Gradually operation, stay at last step after operated one circle and wait for input signal of
reset, restart from first circle.
Constant
No.
Constant name
Settable range
Factory setting
Change during
operation
CE48
Multi-step function mode reset
0 1
0
X