27
6. Constant tables
■
Constant
NO
Name
Description
Setting
value
Factory
setting
Change
during
operation
Com.
add.
Page
Cd-16 Start frequency
Set motor start frequency
0.5 60.0
1.5
HZ
No 144
P47
Cd-17
Upper limiter of
frequency
Set upper limiter of frequency command
10.00
400.00
60.00
HZ
No 145
P60
Cd-18
Lower limiter of
frequency
Set lower limiter of frequency command
0.0
100.00
0HZ No 146
P60
Cd-19
Acce./ dece. of
Joging
The time needed for set frequency
from 0 HZ to 5 Hz
0.0
6000.0
1.0S No 147 P52
Cd-20
Jump frequency 1
0 400.00 0HZ
No
148 P47
Cd-21
Jump frequency 2
Set the middle value of jump frequency, set 0 is
invalid.
0 400.00 0HZ
No
149 P47
Cd-22
Jump frequency
width
Set jump frequency width 0 20.0 0HZ
No
150 P47
Cd-23
DC break
frequency
Start the DC break frequency as HZ when decelerate
to stop. Start frequency (Cd16) when Cd23< start the
DC break frequency (Cd16).
0.0 20.0 1HZ
No
512 P48
Cd-24
DC break
current
Set the inverter rated current as a percentage. Set the
DC break time when start. The setting value is 0.00S,
and the DC break is invalid when start.
0 100
50% No 513 P48
Cd-25
DC break time
when start
The setting value is 0.00S, and the DC break is
invalid when start.
0 10.00 0.00S
No
514 P48
Cd-26
DC break time
when stop
The setting value is 0.00S, and the DC break is
invalid when stop.
0 10.00 0.00S No 515 P48
Cd-27
Prohibited reverse
selectin
0: Reverse
1: Prohibited reverse
0 1 0.00
No 155 P45
Cd-28
Speed search
function selecting
0: Invalid
1: MCK feedback
2: Detected cMCK feedback
3: MCK disconnection start + coast start
0 3 0.00
No 156 P83
Cd-29 TIME
For replay,DOfunction selecting when operation in
timing
0 60000 5S
Yes 157 P55
Cd-30
Analog input
filter time
Set filtered of analog input terminal time, noise will
be filtered, but input reaction will become slow.
1 1000
5
Yes
517 P49
Cd-31 IN1 input gain
Set percentage 100% when input 10V to correspond
selecting function 100%
0 100.0
100.0
%
Yes 518 P49