◆Frequency setting
Constant No.
Constant name
Settable range
Factory setting
Change during
operation
Cd00 Frequency
setting 0 400.00HZ
10.00
0
Description: There are 5 methods to change set frequency. Items A C are methods of panel key operation,
items D-E are methods of external terminal input.
A. At display function, press READ and setting (Cd01=0)
B. Use PROG key to input data (Cd01=0)
C. Use ▼、▲ key to input data (Cd01=0)
D. Use Multi-Step function to setting (Refer to function CE05 to CE55.)
E. Set external voltage
F. Set external current
Notice: Set value should be in accordance with V/F slope (Cd05) and upper limit frequency (Cd17).
Set by function key
A. At display function, press READ and setting (Cd01=0)
F 1 0. 0 0
PROG C d - 0 0
READ 1 0. 0 0
▲▼
X
3 0. 0 0
SET 3 0. 0 0
C d - 0 0
PROG C E - 0 0
PROG 3 0. 0 0
8. Constant setting by function■