60
10. V/F control ■
◆V/F free pattern setting
◆Frequency command
Description: Set frequency command limit to restrict working frequency when motor is running.
O utput
Frequency
Frequency
m axim um
Frequency
m inim um
O peration Frequency
F H
Constant
No.
Constant name
Settable range
Factory setting
Change during
operation
Cd51
Motor rated voltage
50.0 500.0 By
specification
X
Cd52
Motor rated frequency (FA) 0.0
0 400.00 60.0HZ
X
Cd53 Maximum
output
frequency (FMAX)
40.00 400.00
60.0HZ
X
Cd54
Maximum output voltage (VMAX)
0.0 500.0
By specification
X
Cd55
Middle output frequency (FB)
0.0 400.0
3.0HZ
X
Cd56
Middle output voltage (VC)
0.0 500.0
By specification
X
Cd57 Minimum
output
frequency (FMIN)
0.0 400.0
0.5HZ
X
Cd58
Minimum output voltage (VMIN)
0.0 500.0
By specification
X
Constant
No.
Constant name
Settable range
Factory setting
Change during
operation
Cd17 Maximum
frequency 10.00 400.00
60.00
X
Cd18 Minimum
frequency 0.50 100.00
0.00
X