
53
◆Multi-step speeds frequency command
Description: Set by external terminals S1 S6 and switch every step speed. Each step speed will not be
interference, the value never exceeds the maximum range.
Cd12= 2
nd
step frequency setting
Cd13= 3
rd
step frequency setting
Cd14= 4
th
step frequency setting
Cd40= 5
th
step frequency setting
Cd41= 6
th
step frequency setting
Cd42= 7
th
step frequency setting
Cd43= 8
th
step frequency setting
9. Output/ input terminals ■
Constant
No.
Constant name
Settable range
Factory setting
Change during
operation
Cd12 Frequency
command 2 0.00 400.00
20.00
O
Cd13 Frequency
command 3 0.00 400.00
30.00
O
Cd14 Frequency
command 4 0.00 400.00
40.00
O
Cd40 Frequency
command 5 0.00 400.00
45.00
O
Cd41 Frequency
command 6 0.00 400.00
50.00
O
Cd42 Frequency
command 7 0.00 400.00
55.00
O
Cd43 Frequency
command 8 0.00 400.00
60.00
O