This shows the latest firmware version of unit. Press
DOWN
arrow to view the next statistic.
This shows the serial number of circuit board. Press
DOWN
arrow to view the next statistic.
The date and time showed here is when the unit last was powered up. This can be helpful if there
was a power outage to see how long the unit has been on.
Check Sensors - Main Board, Flow meter, and/or Aqua-Sensor.
From the home screen, press the
DOWN
arrow to
ADV. SETUP
. Press the
CHECK
MARK
button.
Press the DOWN arrow to scroll to
DIAGNOSTICS
. Press the
CHECK
MARK
button at
DIAGNOSTICS
.
Press the DOWN arrow to scroll to
CHECK SENSORS.
Press the
CHECK
MARK
button at
CHECK SENSORS
.
MAIN BOARD POSITION:
Position of Home & Program switches. Press
DOWN
arrow to view
the next statistic.
Cycle
Home Switch
Program Switch
Service
Off
Off
Backwash
On
On
Brine Draw/Slow Rinse
On
Off
Fast rinse/Refill
On
On
FLOW METER:
Current pulses per second. (K-Factor) - refer to page 63 to varify correct reading.
Press
DOWN
arrow to view the next statistic.
AQUASENSOR SUPPLY VOLTAGE:
This will be either
PASS
or
FAIL
. If this reading is
FAIL
,
check the Aqua-Sensor connection to the circuit board and to the power supply. Press
DOWN
arrow to view the next statistic.
fw110lt01
may 9 2008
s/n: 00001078
last power up
01-01-08
12:01 pm
system ok
7:32 am 2-1-08
> 5) adv setup
main board position sensor
home: off Pos: off
> 5) diagnostics
> 2) check sensors
flow meter
7 puls/sec
aquasensor supply voltage
2.5vac: pass
Diagnostics
Diagnostics
56
55
CULLIGAN GLOBAL ELECTRONIC CONTROLLER
Содержание GBE
Страница 62: ...Menu Overview Continued on page 61 59 CULLIGAN GLOBAL ELECTRONIC CONTROLLER ...
Страница 63: ...Menu Overview Menu Overview 60 ...
Страница 64: ...Menu Overview Continued from page 59 61 CULLIGAN GLOBAL ELECTRONIC CONTROLLER ...
Страница 65: ...Menu Overview Menu Overview 62 ...
Страница 72: ...Appendix D 69 CULLIGAN GLOBAL ELECTRONIC CONTROLLER ...