SMI21
60
12. EXPERT PROGRAMS
12.1.
Speed Programs
12.1.1.
Types of Inputs in V100 Programs
The table below defines the function associated with each of the inputs in the 4 V100 programs (the color
associated with the input number corresponds to that of the I/O bundle):
Programs
Inputs
V101
V102
V103
V104
In1
ON/OFF
ON/OFF
000 : "In6" setpoint speed
001 : Priority speed 1
010 : Priority speed 2
100 : Priority speed 3
8 combinations:
Coding 8
preprogrammed
speeds
In2
Direction
Direction
In3
Holding
Holding
In4
Fast stop
Fast stop
00 : Fast stop
10 : CCW
01 : CW
11 : Stop, disable error
00 : Fast stop
10 : CCW
01 : CW
11 : Stop, disable error
In5
Speed ramp
Nominal
torque
In6
Speed
Speed
Speed
(if In1 = In2 = In3 = 0)
Nominal torque
Key:
Digital type input
Analog or PWM type input
12.1.2.
Types of Outputs in V100 Programs
For all expert speed programs, 4 configurable output configurations are available (the color associated with
the output number corresponds to that of the I/O bundle):
Out1
Out2
Out3
Out4
Type 1
Hall pulse
Real torque
Direction of rotation
Error
pulse
PWM
Digital
Digital
Type 2
Real speed
Real torque
Motor running
Error
PWM
PWM
Digital
Digital
Type 3
Real speed
Direction of rotation
Motor running
Error
Frequency
Digital
Digital
Digital
Type 4
Real speed
(centered on 50%)
Real torque
(centered on 50%)
00 : error detected
01 : motor running
10 : motor stopped in holding mode
11 : motor stopped and freewheeling
PWM
PWM
Digital combinations
Key:
Digital type output
PWM/Pulse/Frequency type output