SMI21
48
11.3.
"Valve" Group
11.3.1.
"Valve 4 positions" Application Program
Figure
41
The "Valve 4 positions" application program invokes the P101 expert program.
The user can switch to this expert mode at any time to access all the settings by clicking the "Expert Mode"
button.
The values preset in application mode will be loaded directly in expert mode.
It is then impossible to return to this application program.
The user can press the "STOP" button at any time to stop the application quickly.
To restart the motor, the program needs to be reloaded.
Once the settings are complete, press the "Load Program" button to configure the motor.
11.3.1.1. Inputs/Outputs Configuration
Refer to the "I/O Connection" section.
Inputs:
•
IN1: If 0
→ No position setpoint,
if 1
→ Setpoint = "Position 1" Parameter
•
IN2: If 0
→ No position setpoint,
if 1
→ Setpoint = "Position 2" Parameter
•
IN3: If 0
→ No position setpoint,
if 1
→ Setpoint = "Position 3" Parameter
•
IN4: If 0
→ No position setpoint,
if 1
→ Setpoint = "Position 4" Parameter
•
IN5: If 0
→ No action,
if 1
→ Launch homing phase
•
IN6: If 0
→ Stop,
if 1
→ Run
N.B.: if more than 1 input IN1 to IN4 is activated at the same time, the motor switches to stop mode.
Input
connections
Output
connections