12.2.
Position Programs
12.2.1.
Types of Inputs in P100 Programs
The table below defines the function associated with each of the inputs in the 12 P100 programs (the color
associated with the input number corresponds to that of the I/O bundle):
Programs
Inputs
P101
P102
P103
P104
P105
P106
In1
Position 1
Validation
Validation
Validation
Validation
Validation
In2
Position 2
1 to 8
positions
1 to 6
positions
+ Homing
+ ON/OFF
1 to 6
positions
+ Homing
+ ON/OFF
1 to 6
positions
+ Homing
+ ON/OFF
1 to 6
proportional
positions
+ Homing
+ ON/OFF
In3
Position 3
In4
Position 4
In5
Homing
Homing
Speed
ramps
Switch 1:
limit stop
Switch 1:
limit stop
Switch 1:
limit stop
In6
ON/OFF
ON/OFF
Speed
Speed
Fast stop
Switch 2:
limit stop
Inputs
P107
P108
P109
P110
P111
P112
In1
1 to 16
positions
Validation
Validation
Validation
1 to 30
positions
+ Homing
+ ON/OFF
1 to 30
proportional
positions
+ Homing
+ ON/OFF
In2
1 to 14
positions
+ Homing
+ ON/OFF
1 to 14
positions
+ Homing
+ ON/OFF
1 to 14
positions
+ Homing
+ ON/OFF
In3
In4
In5
Homing
In6
ON/OFF
Speed
Switch 1:
limit stop
Fast stop
Switch 1:
limit stop
Switch 1:
limit stop
Key:
Digital type input
Analog or PWM type input