SMI21
116
12.2.4.6. "Tuning" Tab
This tab is used to represent some parameters (speed, position, torque, etc.) in graphic form and modify the
position control loop coefficients. It is common to all the position expert programs.
Figure
176
12.2.4.7. "Limits" Tab
This tab is used to configure the various motor operating limits: nominal and maximum torque (torque peak
authorization) and the power supply overvoltage threshold.
SEQ Figure \* ARABIC 185
This tab is used to view the
selected parameters in graphic
form.
This zone is used to:
- Select the parameters to be
viewed in graphic form
- Set the position correction
factors
- Set the display time
- Export the data (.csv)
Setting the parameters
associated with torque
control.
Summary description of
torque control.
Overvoltage threshold settings: if
this value is exceeded, an error
will be generated.