Product specification
Condair DL
Type A
(
with
booster pump)
Type B
(
without
booster pump)
Sound level
Sound level
approx. 51 dB(A)
approx. 41 dB(A)
Hygiene
Silver ionization cartridge "Hygiene Plus"
Yes
Communication
Remote operating and fault indication
Yes
Modbus RTU and Modbus TCP
Yes
BACnet IP and BACnet MS/TP Master or
Slave Mode
Yes
IoT
Yes
Interfaces
Ethernet
Yes
USB
Yes
RS 485
Yes
Air
Pressure drop (393 ft/min (2 m/s))
approx. 0.16" w.c. (40 Pa)
Max. air velocity
492.13 ft/min (2.5 m/s) (without droplet separator),
787.40 ft/min (4 m/s) (with droplet separator)
Air filter quality before humidification unit
MERV13 or better
Max. admissible air temperature
140 °F (60°C) (before humidification unit)
Water
Connector water supply
ø0.47" (ø12 mm) plug-in coupling or 1/2" male thread adapter (supplied)
Connector water drain
ø0.39" (ø10 mm) plug-in coupling or 1/2" male thread adapter (supplied)
Admissible water supply pressure
working pressure
43.51 ... 101.5 psi (3 ... 7 bar)
working pressure
43.51 ... 101.5 psi (3 ... 7 bar)
Admissible water temperature
41 ... 68 °F (5 ... 20 °C)
Water quality requirements
fully demineralised water from reverse osmosis system with 0.5...15 µS/cm
(
without any additives
), max. 100 cfu/ml
Operating monitoring RO water
min. pressure, max. pressure, pressure after sterile filter, conductivity
Ambient conditions operation
Admissible ambient temperature
41 ... 104 °F (5 ... 40 °C)
Admissible ambient humidity
10 ... 80 %rh, non-condensing
Ambient conditions storage
Admissible ambient temperature
41 ... 104 °F (5 ... 40 °C)
Admissible ambient humidity
10 ... 75 %rh, non-condensing
Protection class
Control unit
IP21
Central unit
IP21
Certificates
Certificates
CE, DGUV, EAC, BTL
1)
Larger installation length on demand
2)
Larger dimensions on demand
3)
Larger capacities on demand (consider possible number of steps for capacity range!)
Note: For systems "Type A" (with booster pump), the minimum output of 11.02 lb/hr (5 kg/hr) can only be regulated at a flow
pressure <58.0 psi (<4.0 bar). With a flow pressure of ≥58.0 psi (≥4.0 bar), we recommend a minimum output of 22.04 lb/hr
(10 kg/hr) for "Type A" systems.
4)
The nominal control accuracy may not always be available, because various factors (temperature control, water recycling,
flap valve systems, etc.) may affect the accuracy.
5)
These values can be smaller influenced by other limit values such as humidity, volume flow or air speed! The values are to be
understood as theoretical appoximate values, which are determined by the number of nozzles and their size. The maximum
capacity values are achieved only with a booster pump.