Common Equipment Faults Menu
Refer to Figure 3-9.
Fault/Alarm
Possible Problem and Action
BATTERY/CLOCK
M&C battery voltage or clock fault. Indicates a low voltage in the memory
battery.
Note:
Typically will be active when a demodulator has been Hard Reset, or
the firmware has been changed, and the demodulator is first turned On. If the
fault occurs without a firmware change or hard reset of the demodulator,
replace the battery on the demodulator board (PL/5746).
-12 VOLT SUPPLY
-12V power supply fault. Indicates a high or low voltage condition. Level is
±
5%.
Check the -12V line from the power supply or on the board. Check TP17 on
the demodulator board (PL/5746), to verify the proper -12V monitor voltage.
If this voltage is not at the proper level, this would indicate the power supply
is faulted. Return demodulator for repair.
+12 VOLT SUPPLY
+12V power supply fault.
Use the same procedure as with -12V Supply fault. To verify the +12V power
supply voltage, check TP19 on the demodulator board (PL/5746). A voltage
of 12V (± 5%), will be monitored when the +12V is at the proper level.
+5 VOLT SUPPLY
+5V power supply fault.
Use the same procedure as with -12V fault. To verify the +5V power supply
voltage, check TP5 on the demodulator board (PL/5746). A voltage of 5V (±
5%), will be monitored when the +5V is at the proper level.
CONTROLLER
Controller fault. Indicates loss of power in the M&C card.
Note:
Typically indicates the controller has gone through a power On-Off
cycle.
LNB
LNB fault. Indicates loss of LNB during operation
Note:
Typically indicates the LNB has gone through a power On-Off cycle.
Содержание SDM-2020
Страница 20: ...SDM 2020 Satellite Demodulator Introduction Rev 3 1 5 2 Data and symbol rates become effective January 1999...
Страница 30: ...SDM 2020 Satellite Demodulator Introduction Rev 3 1 15 Figure 1 7 16QAM 3 4 7 8 Reed Solomon Decoder...
Страница 32: ...SDM 2020 Satellite Demodulator Introduction Rev 3 1 17 This page is intentionally left blank...
Страница 35: ...SDM 2020 Satellite Demodulator Installation Rev 3 2 3 Figure 2 1 Typical Rack Installation...
Страница 57: ...SDM 2020 Satellite Demodulator Operation Rev 3 3 13 This page is intentionally left blank...
Страница 65: ...SDM 2020 Satellite Demodulator Operation Rev 3 3 21 This page is intentionally left blank...
Страница 72: ...Operation SDM 2020 Satellite Demodulator 3 28 Rev 3 This page is intentionally left blank...
Страница 75: ...SDM 2020 Satellite Demodulator Operation Rev 3 3 31 This page is intentionally left blank...
Страница 92: ...Operation SDM 2020 Satellite Demodulator 3 48 Rev 3 This page is intentionally left blank...
Страница 121: ...Data Interfaces SDM 2020 Satellite Demodulator A 20 Rev 3 This page is intentionally left blank...
Страница 141: ...Data Interfaces SDM 2020 Satellite Demodulator A 40 Rev 3 This page is intentionally left blank...
Страница 157: ...Data Interfaces SDM 2020 Satellite Demodulator A 56 Rev 3 This page is intentionally left blank...
Страница 165: ...Data Interfaces SDM 2020 Satellite Demodulator A 64 Rev 3 This page is intentionally left blank...
Страница 203: ...Remote Control Operation SDM 2020 Satellite Demodulator B 28 Rev 3 This page is intentionally left blank...
Страница 209: ...Fast Option SDM 2020 Satellite Demodulator C 6 Rev 3 This page is intentionally left blank...
Страница 212: ...SDM 2020 Satellite Demodulator Glossary Rev 2 g 3 W Watt...
Страница 213: ...Glossary SDM 2020 Satellite Demodulator g 4 Rev 3 This page is intentionally left blank...