Technote 2: Setting up MS-551 Stereo Modulators
Vestigial Side Band TV Stereo Modulators generate an analogue TV channel from the audio
and video signals .MS-551 Stereo modulators comprise SAW filtering for maximum harmonic
reduction and true VSB response for adjacent channel operation.
IMPORTANT:
Layout of the modules must be as shown above. Power Supply (FA-310/312)
must be located on the far left hand side and launch amplifier (PA-720) must be the next
module in the chain. Please look at the above picture.
AIM PROGRAMMER TO IR SENSOR LOCATED ON EACH MODULATOR
WHEN PROGRAMMING
Programming of Modules
Ensure the following prior to programming:
•
It is necessary to connect all the modules to the support frame SP-226 (code 9120130)
for the system to function.
•
It is also recommended that you make the earth connection to the building using a cable
with a section of at least 4 mm.
•
Ensure that you have the Alcad programmer PS-003 with
firmware version 4.7
or later.
•
Power supply/Control cable must be plugged into each module.
DO NOT ADD OR
REMOVE
modules without disconnecting mains supply power from wall outlet. Always
disconnect the equipment, and then reconnect it to the mains supply so that the
amplifier recognises the new module. Failure to do so can cause equipment to fail.
Launch Amplifier
Power Supply