LBC-4000 L-Band Up/Down Converter System
Revision 6
Specifications
2–3
MN-LBC-4000
2.1.7.5 Modular Design
LBC-4000: Two IDU Module bays (‘CONV A’ and ‘CONV B’) are located behind the drop-down
front panel.
LBC-4000-ST: One internal ‘CONV A’ IDU Module bay.
2.1.7.5.1
L-Band Up Converter IDU Module
Input Frequency
Standard: 70 MHz
±
18 MHz
Optional: 140 MHz
±
36 MHz
Output Frequency
950 MHz to 2000 MHz, 1 kHz steps
Optional: 950 to 2150 MHz, 1 kHz steps
Input/Output Impedance
50Ω
Input Return Loss
18 dB minimum
Output Return Loss
15 dB minimum
Input connector
BNC female
Output connector
Type ‘N’ female
Gain
25 dB
±
1 dB nominal at minimum attenuation
Ripple
±
.5 dB over any
±
18 MHz for standard 70 MHz IF units
±
.5 dB over any
±
36 MHz for optional 140 MHz IF units
Slope
0.05 dB/MHz
User Attenuation Range
0 to 50 dB, in 0.25 dB steps (Standard) or 0.1 dB steps (Optional)
Input Power Level
Up to
±
10 dBm maximum
Output Power, P1dB
+10 dBm minimum
Third Order Intercept
+20 dBm minimum
Carrier Spurious
-60 dBc
Non-Carrier Spurious
-75 dBm
Transmit Phase Noise
Exceeds MIL-STD-188-164A
Stability
Over Time
±
1 X 10
-9
/Day
Over Temp
±
1 x 10
-8
32 to 122°F (0 to 50°C)
Содержание LBC-4000
Страница 36: ...LBC 4000 L Band Up Down Converter System Revision 6 Installation and Startup 3 8 MN LBC 4000 BLANK PAGE...
Страница 64: ...LBC 4000 L Band Up Down Converter System Revision 6 Firmware Update 5 16 MN LBC 4000 BLANK PAGE...
Страница 134: ...LBC 4000 L Band Up Down Converter System Revision 6 Serial Interface Operation 8 24 MN LBC 4000 BLANK PAGE...
Страница 140: ...LBC 4000 L Band Up Down Converter System Revision 6 Appendix A A 6 MN LBC 4000 Notes...
Страница 147: ......
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...