LBC-4000 L-Band Up/Down Converter System
Revision 6
Firmware Update
5–12
MN-LBC-4000
5.4.2 “CReflash” Used to Upload the Firmware Files
1. The “CReflash” utility is provided with the firmware download.
2. Serial-only (i.e., non-Ethernet) units must use this procedure.
Do these steps:
1. From the temporary folder – Locate, and then double-click, the “CReflash” filename or
icon. The CReflash utility opens:
2. Enter your upload parameters information into CReflash:
a. Left-click in the “IP Address:” text box, and enter the default Management IP
Address.
b. Left-click in the “Local Filename:” text box. Then, click
[Browse]
and navigate to
the temporary folder created earlier. Click on the firmware “bin” filename, and
then click
[Open]
. The filename will appear in the “Local Filename:” text box.
c. Make sure the drop-down list remains set to “
bulk:
”.
d. Click
[Start]
to begin the upload process. If the information was correctly entered
into CReflash, the utility displays an animated progress bar at the bottom of the
window, along with a series of messages:
•
“Opening FTP”
•
“Sending data file to modem:”
•
“Writing FLASH: # of #”
•
“Success!”
3. When done, click
[Cancel]
to exit CReflash.
Содержание LBC-4000
Страница 36: ...LBC 4000 L Band Up Down Converter System Revision 6 Installation and Startup 3 8 MN LBC 4000 BLANK PAGE...
Страница 64: ...LBC 4000 L Band Up Down Converter System Revision 6 Firmware Update 5 16 MN LBC 4000 BLANK PAGE...
Страница 134: ...LBC 4000 L Band Up Down Converter System Revision 6 Serial Interface Operation 8 24 MN LBC 4000 BLANK PAGE...
Страница 140: ...LBC 4000 L Band Up Down Converter System Revision 6 Appendix A A 6 MN LBC 4000 Notes...
Страница 147: ......
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...