LBC-4000 L-Band Up/Down Converter System
Revision 6
Serial Interface Operation
8–16
MN-LBC-4000
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Mute State
MUT_
5 bytes,
alphabetic
Command or Query.
Use “MUT” to mute or unmute the specified module.
Set or return in the form MUT_y_xxx where:
y=A (Conv A)
y=B (Conv B)
xxx=ON (mute)
xxx=OFF (unmute)
MUT_
MUT_y_
MUT_y_xxx
Online State
N/A
1 byte,
alphabetic
Query only.
Use “ONL” to return which converter (slot) is ONLINE.
Return in the form ONL_y where:
y=A (Conv A)
y=B (Conv B)
N/A
ONL_
ONL_y
Retrieve Part
Number
N/A
1 byte,
alphabetic
Query only.
Returns the factory-assigned CEFD part number for the Unit, Conv
A, or Conv B.
Return in the form PNM_y_ where:
y=U (Unit)
y=A (Conv A)
y=B (Conv B)
Query Examples:
<0001/PNM_U_{cr} (Returns the Unit part number)
<0001/PNM_A_{cr} (Returns the Conv A part number)
<0001/PNM_B_{cr} (Returns the Conv B part number)
Note: This number is the DOTCODE at the time the part was
manufactured. The DOTCODE may be up to 96 printable ASCII
characters long.
N/A
PNM_y_
PNM_y_x..x
Содержание LBC-4000
Страница 36: ...LBC 4000 L Band Up Down Converter System Revision 6 Installation and Startup 3 8 MN LBC 4000 BLANK PAGE...
Страница 64: ...LBC 4000 L Band Up Down Converter System Revision 6 Firmware Update 5 16 MN LBC 4000 BLANK PAGE...
Страница 134: ...LBC 4000 L Band Up Down Converter System Revision 6 Serial Interface Operation 8 24 MN LBC 4000 BLANK PAGE...
Страница 140: ...LBC 4000 L Band Up Down Converter System Revision 6 Appendix A A 6 MN LBC 4000 Notes...
Страница 147: ......
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...