LBC-4000 L-Band Up/Down Converter System
Revision 6
Ethernet Interface Operation
7–21
MN-LBC-4000
7.5.3.5
Config | Serial
Use this page to configure the operating parameters over the EIA-485/232 serial interface.
Figure 7-15. Config | Serial page
Serial
Click
[Refresh]
to update screen.
Serial
Name
Description
Interface Type
Use the drop-down menu to select the operating serial mode as RS-485 or RS-232.
Remote Address
Enter a valid remote control address from 0001 to 9999.
Baud Rate
Use the drop-down menu to select the operating baud rate as 1200, 2400, 4800,
9600, 19200, or 38400 baud.
Data bits – Prity – Stop bits Use the drop-down menu to select the asynchronous character format as 8-N-1 (8
data bits, no parity, 1 stop bit); 7-O-2 (7 data bits, odd parity, 2 stop bits); or 7-E-2 (7
data bits, even parity, 2 stop bits).
Click
[Change Serial Configuration]
to update the changes.