LBC-4000 L-Band Up/Down Converter System
Revision 6
Ethernet Interface Operation
7–19
MN-LBC-4000
7.5.3.3
Config | Utility
Use this page to configure a variety of converter operating parameters.
Figure 7-13. ‘Config | Utility’ Page
Utility
Click
[Refresh]
to update screen.
Name
Description
Date
Enter a date in the form MM/DD/YY (where MM = month [01 to 12],
DD = day [01 to 31], and YY = year [00 to 99]).
Time
Enter a time in the form HH:MM:SS (where HH = hour [00 to 23], MM = minutes [00
to 59], and SS = seconds [00 to 59]).
Click [Change Date/Time] to update settings.
Circuit ID
Enter a Circuit ID string of up to 48 characters – 24 characters per line.
Click [Change CID] to update settings.
Current Active Firmware
Image
This read-only section identifies the selected Current Active Firmware Image. In this
example, Image 2 is the Current Active Firmware Image.
Next Reboot Image
Use the drop-down menu to select Image 1 or 2. Press [Submit] when done.
Fault Relay Logic
Use the drop-down menu to select the Fault Relay Logic as Normal or Invert, and
then click [Submit].
Perform Soft Reboot
Click [Reboot Now] to reboot the unit using the Current Active Firmware Image.
Firmware Information
This read-only scrollable window identifies the Bootrom, Bulk Image#1 and Bulk
Image #2 firmware information.
Содержание LBC-4000
Страница 36: ...LBC 4000 L Band Up Down Converter System Revision 6 Installation and Startup 3 8 MN LBC 4000 BLANK PAGE...
Страница 64: ...LBC 4000 L Band Up Down Converter System Revision 6 Firmware Update 5 16 MN LBC 4000 BLANK PAGE...
Страница 134: ...LBC 4000 L Band Up Down Converter System Revision 6 Serial Interface Operation 8 24 MN LBC 4000 BLANK PAGE...
Страница 140: ...LBC 4000 L Band Up Down Converter System Revision 6 Appendix A A 6 MN LBC 4000 Notes...
Страница 147: ......
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...