LBC-4000 L-Band Up/Down Converter System
Revision 6
Serial Interface Operation
8–11
MN-LBC-4000
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Configure Mute
Mode
CMM_y_xxx
5 bytes,
alphabetic
Command or Query.
Use “CMM” to set or return the mute mode.
Set or return in the form CMM_y_xxx where:
y=A (Conv A)
y=B (Conv B)
xxx=ON (mute)
xxx=OFF (unmute)
Command Example:
<0001/CMM_A_OFF{cr} (Unmutes Converter A)
CMM_y_xxx
CMM_y_
CMM_y_xxx
Concise
Maintenance
Status
N/A
85 bytes,
numeric
Query only.
Use “CMS” to return a summarized version of the maintenance
status. Returns status info in the form
“CMS_aaa.abbb.bccc.cddd.deee.efff.fggg.ghhh.hiii.ijjj.jkkk.klll.lmmm
.mnnn.nooo.oppp.pqqq.q{cr}{lf}” where:
aaa.a=12 VDC supply #1 in volts
bbb.b=8 VDC supply #1 in volts
ccc.c=5 VDC supply #1 in volts
ddd.d=12 VDC supply #2 in volts
eee.e=8 VDC supply #2 in volts
fff.f= 5 VDC supply #2 in volts
ggg.g=Ref Osc tuning in volts
hhh.h=Converter A IFLO tuning in volts
iii.i= Converter A RFLO tuning in volts
jjj.j=Converter A Input Power in dBm (Reserved for future use)
kkk.k=Converter A Output Power in dBm (Reserved for future
use)
lll.l= Converter A temperature in degrees C
mmm.m=Converter B IFLO tuning voltage in volts
nnn.n= Converter B RFLO tuning voltage in volts
ooo.o=Converter B Input Power in dBm (Reserved for future use)
ppp.p=Converter B Output Power in dBm (Reserved for future
use)
qqq.q=Converter B temperature in degrees C
N/A
CMS_
CMS_a…q
Содержание LBC-4000
Страница 36: ...LBC 4000 L Band Up Down Converter System Revision 6 Installation and Startup 3 8 MN LBC 4000 BLANK PAGE...
Страница 64: ...LBC 4000 L Band Up Down Converter System Revision 6 Firmware Update 5 16 MN LBC 4000 BLANK PAGE...
Страница 134: ...LBC 4000 L Band Up Down Converter System Revision 6 Serial Interface Operation 8 24 MN LBC 4000 BLANK PAGE...
Страница 140: ...LBC 4000 L Band Up Down Converter System Revision 6 Appendix A A 6 MN LBC 4000 Notes...
Страница 147: ......
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...