LBC-4000 L-Band Up/Down Converter System
Revision 6
Serial Interface Operation
8–10
MN-LBC-4000
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Concise
Configuration
Status
N/A
52 bytes,
numeric
Query only.
Use “CCS” to return a summarized version of the RCS query.
Returns status info in the form
“CCS_aaaaa.aaabb.bbcd.defffff.fffgg.gghi.ijklmnnnopqqqqrs{cr}{lf}”
where:
aaaaa.aaa=Conv A frequency in MHz
bb.bb=Conv A attenuation in dB
c=Conv A mute state (0=unmuted, 1=muted)
d.d=Conv A slope adjustment level
e=Conv A online/offline (redundancy)
fffff.fff=Conv B frequency in MHz
gg.gg=Conv B attenuation in dB
h=Conv B mute state (0=unmuted, 1=muted)
i.i=Conv B slope adjustment level
j=Conv B online/offline (redundancy)
k=Converter redundancy mode
l=auto fault recovery (1=auto, 0=manual)
m=External Ref present (0=none, 1=present)
nnn=Internal Ref Osc adjustment level (000-255)
o=remote mode (1=remote, 0=local)
p=remote interface (0=EIA-232, 1=EIA-485)
qqqq=remote address (0001-9999)
r=remote baud rate (0=38400, 1=19200, 2=9600, 3=4800,
4=2400, 5=1200)
s=remote data format (0=8N1, 1=7E2, 2=7O2)
N/A
CCS_
CCS_a…s
Содержание LBC-4000
Страница 36: ...LBC 4000 L Band Up Down Converter System Revision 6 Installation and Startup 3 8 MN LBC 4000 BLANK PAGE...
Страница 64: ...LBC 4000 L Band Up Down Converter System Revision 6 Firmware Update 5 16 MN LBC 4000 BLANK PAGE...
Страница 134: ...LBC 4000 L Band Up Down Converter System Revision 6 Serial Interface Operation 8 24 MN LBC 4000 BLANK PAGE...
Страница 140: ...LBC 4000 L Band Up Down Converter System Revision 6 Appendix A A 6 MN LBC 4000 Notes...
Страница 147: ......
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...