LBC-4000 L-Band Up/Down Converter System
Revision 6
Ethernet Interface Operation
7–5
MN-LBC-4000
7.3.1.1
Configure HyperTerminal for Telnet Remote Control Operation
See Figure 7-3. Do these steps:
1. Make sure to define the Connect To Telnet connection properties correctly (
File
Properties
) (Figure 7-3, left):
a. Enter the unit’s Traffic/Management IP Address as the “Host address” (e.g.,
192.168.1.1).
b. Enter TCP
Port 23
as the “Port number”.
c. Set “Connect using” to TCP/IP (Winsock) instead of COM1 or COM2.
d. Click
[OK]
to save your settings.
2. For ASCII Setup (
File
Properties
Settings
ASCII Setup
) (Figure 7-3, right side):
a. Check the “Send line ends with line feeds” option in the ‘ASCII Sending’ section.
b. Check the “Append line feeds to incoming line ends” option in the ‘ASCII
Receiving’ section.
c. Click
[OK]
to save your settings.
Figure 7-3. Configure HyperTerminal