4-33
Compaq Professional Workstation AP200 Maintenance and Service Guide
SCSI Test Error Codes
Continued
Error Code
Description
Recommended Action
XXXX-40
Target timed out.
Replace the indicated device.
XXXX-41
SCSI bus stayed busy.
Replace the indicated device.
XXXX-42
ACK/REQ lines bad.
Replace the indicated device.
XXXX-43
ACK did not deassert.
Replace the indicated device.
XXXX-44
Parity error.
Replace the indicated device.
XXXX-50
Data pins bad.
Replace the indicated device.
XXXX-51
Data line 7 bad.
Replace the indicated device.
XXXX-52
MSG, C/D, and/or I/O lines bad.
Replace the indicated device.
XXXX-53
BSY never went busy.
Replace the indicated device.
XXXX-54
BSY stayed busy.
Replace the indicated device.
XXXX-60
Controller CONFIG-1 register bad.
Replace the indicated device.
XXXX-61
Controller CONFIG-2 register bad.
Replace the indicated device.
XXXX-65
Media not unloaded.
Replace the indicated device.
XXXX-90
Fan failure.
1. Ensure fan(s) connected.
2. Replace nonfunctional fan(s).
XXXX-91
Over Temperature.
1. Ensure proper air flow.
2. Perform required maintenance and cleaning.
XXXX-99
Autoloader reported tapes not
loaded properly.
1. Install tape(s) in autoloader tape drive
according to test instructions.
2. Change autoloader magazine.