4-27
Compaq Professional Workstation AP200 Maintenance and Service Guide
CD-ROM Drive (IDE)
Table 4-20
CD-ROM Drive (IDE) Test Error Codes
Error
Code
Description
Recommended Action
3301-xx
CD-ROM drive read test failed.
The following steps apply to error codes error codes
3301-xx through 3305-xx and 6600-xx through
6623-xx:
3305-xx
CD-ROM drive seek test failed.
1. Replace the CD media and retest.
6600-xx
ID test failed.
2. Check the jumper settings on the CD-ROM drive.
6600-xx
ID test failed.
3. Verify that the speaker is connected.
6605-xx
Read test failed.
4. Check and/or replace the power and signal cables
and retest.
6608-xx
Controller test failed.
5. Replace the CD-ROM drive and retest.
6623-xx
Random read test failed.
Tape Drive
Table 4-21
Tape Drive Test Error Codes
Error
Code
Description
Recommended Action
1900-xx
Tape drive ID test failed.
The following steps apply to error codes 1900-xx
through 1906-xx:
1901-xx
Tape drive servo test failed.
1. Replace the tape cartridge and retest.
1902-xx
Tape drive format or format verification test
failed.
2. Check the switch settings and terminations on the
tape drive.
1903-xx
Tape drive sensor test failed.
3. Check and/or replace the signal cable and retest.
1904-xx
Tape drive BOT/EOT test failed.
4. Replace the tape drive and retest.
1905-xx
Tape drive read test failed.
5. Replace the system board and retest.
1906-xx
Tape drive write/read/compare failed.