23
Status
Activate
Absent
Absent
Absent
1
2
3
4
ID Description
Power suppl. 1
Power suppl. 2
Power suppl. 3
Power suppl. 4
Area 2
Area 3
Area 4
Area 5
Area 6
Area 7
Area 8
Area 1
Display tamper
Display technical alarms
Area
Tamper alarm cycles
Unlimited
Cycles
0
Technical alarms cycles (bus / voltage levels)
Unlimited
Cycles
0
Power supply units
Send message options
Send detailed events SMS
Send Email messages
Send digital communication
Send notification to the App
Options
Absent
Absent
Absent
Absent
5
6
7
8
Power suppl. 5
Power suppl. 6
Power suppl. 7
Power suppl. 8
Tamper enabled
Network alarm signalling delay (hh:mm:ss)
Battery alarm signalling delay (hh:mm:ss)
00:00:55
00:05:00
Reading analogue values
Output 1 voltage
Output 2 voltage
Output 3 voltage
Tamper voltage
Tamper power supplier
Aux 1 voltage
Output bus voltage
Aux 2 voltage
Read
3.2.2 Power supply units
See description
Status / ID / Description on page 87
.
STATUS / ID / DESCRIPTION
STATUS/DESCRIPTION PANEL
Column showing the names of the areas in the system. To edit names, see
"3.6 Areas" on page 37
.
• Tamper Enable:
enables device tamper.
Selected [Reg. 19]
• Network alarm signalling delay (hh:mm:ss):
time box, allows you to set the alarm delay caused by a power outage. On expiry of this time
an alarm will be generated, and if programmed, messages will be sent (SMS, voice, email). No
alarm will be generated if the situation returns to normal before expiry of the timer.
Maximum
60 sec [Reg. 20]
• Battery alarm signalling delay (hh:mm:ss):
time box, allows you to set the alarm delay caused by a battery fault. On expiry of this time an
alarm will be generated, and if programmed, messages will be sent (SMS, voice, email). No alarm
will be generated if the situation returns to normal before expiry of the timer.
Maximum 5 min
[Reg. 21]
Allows you to choose to which areas the Tamper alarm generated by the device is sent.
At least one area to which the tamper alarms generated by
the device are to be signalled must be assigned to each active device [Reg. 5]
• Unlimited:
allows you to generate infinite cycles of tamper alarms. If not selected, enables the Cycles box.
Selected [Reg. 12]
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of tamper alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
• Output 1 voltage:
displays the voltage value of open collector output number 1 if enabled.
• Output 2 voltage:
displays the voltage value of open collector output number 2 if enabled.
• Output 3 voltage:
displays the voltage value of open collector output number 3 if enabled.
• Tamper voltage:
displays the analogue voltage value of the 24H input.
• Power supply unit voltage:
displays the voltage value at the input of switching power supply unit Art. 30076101. The typical voltage value is
13.8 Vdc +/- 2%.
• Output bus voltage:
displays the voltage value at the output of the BUS power supply unit between terminals V+ and V- BUS Out.
• Aux 1 voltage:
displays the voltage value at the output between terminals V+ V- Aux 1.
• Aux 2 voltage:
displays the voltage value at the output between terminals V+ V- Aux 2.
Allows you to choose to which areas the technical alarms generated by the device are sent.
At least one area to which the technical alarms
generated by the device are to be signalled must be assigned to each active device [Reg. 6]
AREAS PANEL
AREA
OPTIONS
DISPLAY TAMPER
TAMPER ALARM CYCLES
READING ANALOGUE VALUES
DISPLAY TECHNICAL ALARMS
CONFIGURATIONS PANEL
See description
Send Message options on page. 89
.
All active devices must permit the control panel to send notification to the digital communicator for events generated by the device itself [Reg. 16].
SEND MESSAGE OPTIONS