32
This section is for configuring the basic behaviour of the zone. In particular, you can associate the type of operation to the zone.
ZONE
• Type / subtype:
selects the type of zone from four possibilities: Alarm, Command, Sabotage, Fault Once you have made your selection, the
field below (subtype) will show a series of possible choices, depending on the type of selection made (
See page 94
).
There must be a zone configured as Type: fault - Subtype: zone fault [Reg. 1]. There must be a zone configured as Type: fault -
Subtype: robbery fault [Reg. 2]. There must be a zone configured as Type: fault - Subtype: siren fault [Reg. 3]. All alarm, fault and
command zones must be set to double or triple balance or double with EOL. The sabotage zones must be set to single or double or
triple or triple with jamming or double with EOL [Reg. 4]
• Areas associated with zone:
determines which areas the zone will be associated with.
All active devices must have at least one associated
area. [Reg. 37]
• Areas Logic:
• OR: the selected actions are performed if the conditions arise in any of the areas associated with the zone.
• AND: the set actions are performed only if the conditions arise in all of the areas associated with the zone.
• Inactivity:
allows an action to be generated if a zone remains inactive beyond a maximum time limit.
• No function: no action is performed.
• Fault: an alarm fault is generated.
• Auto-activation: the alarm for the area associated to the zone is activated.
• Inactivity time (minutes):
field for setting the maximum inactivity time.
• Instant activation:
if selected, the zone command instantly activates the areas to which it is associated.
• Forced activation:
if selected, the zone command or inactivity activates the areas to which it is associated, forcing the activation lock conditions.
• Send message options:
See description
Send Message options on page. 89
.
• Alarm cycles
• Unlimited: allows you to generate infinite alarm cycles. If not selected, enables the Cycles box.
Selected [Reg. 40]
• Cycles: if the Unlimited checkbox is not active, this box determines the number of alarm cycles that the zone can generate within an
activation cycle (from one activation to the next).
• Cameras:
This section is for setting a camera to start acquiring the frames upon violation of the zone. The frames obtained can be sent by MMS
and e-mail or notified to the Vedo App.
• Source: drop-down menu; allows you to choose the PAL/IP module to which the camera to be used for shooting the frames
is connected.
• Camera: drop-down menu; allows you to choose the camera that will shoot the frames, from those connected to the PAL/
IP device.
• Groups in AND (only for zone type: Alarm):
The Groups in AND are eight virtual zones which can be constructed on the basis of the real
zones, whether radio or wired. The aim of such a function is to cause the generation of an event,
e.g. an alarm, conditional upon the violation of more than one area. For this purpose, there is a
drop-down menu from which you can associate the zone with any of these eight areas. You need
to associate more than one zone to a Group in AND in order to obtain the expected result. For the
behaviour of Groups in AND, (see
"3.5 Groups in AND" on page 36
).
• Reaction type (only for zone type: Alarm/Burglary):
See description of reaction type on page 95.
• Attributes (only for zone type: Alarm):
See attributes description on page 96.
• Command type:
See description of command type on page 96.