3.12.3 Digital communicator contacts list
There must be at least one digital communicator selected or at least one telephone configured in the phone book (there must be at least one telephone
number in the phone book or in the digital communicator contacts list) [Reg. 69]
The control panel has a digital communicator to Contact ID standard, which is useful for interfacing correctly with a monitoring control panel.
The Contact ID communication function is currently supported only by the PSTN line interface.
This is the section for entering the telephone numbers to be contacted digitally, and for configuring the connection procedures for each contact on
the contacts list.
Numerical box, uniquely identifies the position in the contacts list.
Alphanumeric box for entering the ID of the monitoring control panel to contact.
Alphanumeric box for entering the telephone number for the company contracted to provide the monitoring and telephone checking service.
Drop-down menu, allows you to select the format of communication to the monitoring control panel. Only Contact ID standard is currently available.
Select a communication protocol for each phone number entered. [Reg. 73]
alphanumeric code for entering the code provided by the monitoring control panel. Also enables the monitoring control panel automatically to
recognise the system making the communication.
The user code must be specified for each phone number entered [Reg. 76]
Checkbox; if selected, ensures that the area code is sent to the monitoring control panel (see Areas menu) and not the customer code set in the line.
This is useful in the case of multiple-user systems.
Numerical box for entering the frequency, expressed in hours, of the periodic test. If you enter 24, the test will be carried out 24 hours after the start
date and every 24 hours thereafter.
Numerical box for entering the number of call attempts that the system will make even in the event of failure to connect to the monitoring control
panel.
The number of call attempts must be = 1 for each phone number entered [Reg. 75]
Not supported
Checkbox for enabling the periodic test function.
The periodic test must be active for each phone number entered [Reg. 72] The test period must be
<= 25 hours for each phone number entered [Reg. 74]
Start date of the periodic test.
The start date of the periodic test must precede the current date for each phone number entered [Reg. 77]
ID
DESCRIPTION
NUMBER TO CALL
PROTOCOL
CUSTOMER CODE
SEND AREA CODE
TEST PERIOD
CALL ATTEMPTS
HANDS-FREE AFTER REPORT
ENABLE PERIODIC TEST
PERIODIC TEST START DATE
Checkbox; if selected, allows the selected user to stop the flow of calls directly from the telephone using the Hash (#) and Asterisk (*) keys. The "End
Call With Keys" option must be enabled in Telephone Options.
Checkbox; if selected, enables the selected user to receive SMS/email/MMS sent from the control panel.
STOP CALLS
RECEIVING SMS / EMAIL / MMS