27
Column showing the names of the areas in the system. To edit names, see
"3.6 Areas" on page 37
.
Allows you to choose to which areas the Tamper alarm generated by the device is sent.
At least one area to which the tamper alarms generated by
the device are to be signalled must be assigned to each active device [Reg. 5]
Allows you to select the areas about which visual and/or aural activation/deactivation information can be sent.
To each active device must be
assigned at least one area to which information regarding optical and/or acoustic activation/deactivation can be sent [Reg. 23]
AREAS PANEL
AREA
DISPLAY TAMPER
DISPLAY SYSTEM STATUS
• Serial number:
the siren output serial number will appear the moment it is acquired.
• Type:
drop-down menu; the moment the radio code from the peripheral is acquired, it allows you to establish whether the acquired code will
belong to a radio siren or to a radio output. This will ensure the acquisition of a correct code for the type of peripheral and will set, on the
control panel, the right method of communication with the peripheral.
• Acquire:
for starting the code acquiring phase for the output corresponding to the selected position, by means of the radio expansion module
with which it is associated.
• Delete:
deletes the code of the selected position, making it available again to be associated to another radio peripheral (output or siren).
• LED intermittence timeout:
for future uses.
• Siren volume:
future uses.
• Timeout activation:
for future uses.
• Sound on siren start-up:
for future uses.
• Sound on activation/deactivation:
for future uses.
• Led activation on siren start-up:
for future uses.
• LED activation on activation/deactivation:
for future uses.
• LED enabled:
for future uses.
• Radio monitoring time (minutes):
enables setting of a time period beyond which a fault signal is sent if the siren does not respond.
• Read:
when this key is pressed the radio signal is read. The Minimum RSSI Acquisition value must be 40 RSSI.
RSSI is the power of the radio signal between the siren in use and the radio transmitter to which it is associated, where 0 is no signal and 100 is the
maximum value that can be obtained
.
RADIO OUTPUT PROPERTIES
SIREN OPTIONS
RSSI (SIGNAL LEVEL INDICATOR 0-100)
CONFIGURATIONS PANEL
• Disable battery check:
if this option is selected, the operational check procedure for the battery powering the siren will be disabled.
NOT
selected [Reg. 26]
OTHER OPTIONS
See description on page 90.
EVENT 1 / 2 / 3 / 4
See description on page 90.
EVENTS ASSOCIATION (AND/OR)
• Unlimited:
allows you to generate infinite cycles of sabotage alarms. If not selected, enables the Time box.
• Time:
if the Unlimited checkbox is not active, this box determines the number of sabotage alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
SABOTAGE CYCLES
• Unlimited:
allows you to generate infinite cycles of malfunction alarms. If not selected, enables the Time box.
• Time:
if the Unlimited checkbox is not active, this box determines the number of malfunction alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
MALFUNCTION ALARM CYCLES
See description
Send Message options on page. 89
.
All active devices must permit the control panel to send notification to the digital communicator for events generated by the device itself [Reg. 16].
SEND MESSAGE OPTIONS
See description on page 91.
BEHAVIOUR