• Unlimited:
provides indications even with the system activated, without any time limits. If not selected, enables the Time box. To guarantee conformity
with standards CEI EN 50131-1 and 50131-3, this option must be disabled.
NOT selected [Reg. 17]
• Seconds:
if the Unlimited checkbox is not checked, this box establishes the duration, in seconds, of the display of information on the device when
the system is activated.
=0 [Reg. 17] The alarm memory signal on the control devices is always visible with the system off even if the system
status is not visible (e.g.: setting the display time of the system zero status)
• Unlimited:
allows you to generate infinite cycles of tamper alarms. If not selected, enables the Cycles box.
Selected [Reg. 12]
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of tamper alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
Allows you to choose to which areas the Tamper alarm generated by the device is sent.
Allows you to choose to which areas the technical alarms generated by the device are sent.
• Enable proximity reader:
enables the RFID reader on board the keypad (keypads Art. VEDOLCDPRO only).
• Quick activation:
activates the system (total / partial / scenarios) without asking for the user code (total or partial activations of the system will
not be allowed).
NOT selected [Reg. 14]
• Send quick alarms with function key:
sends alarms when a function key (F1, F2, F3, F4) on the keypad is pressed.
• Display areas status:
authorises the device to display the status of the areas.
Selected [Reg. 18]
• Display alarm memory:
authorises the device to display the alarm memory.
• Display open zones:
authorises the device to display the open zones.
Selected [Reg. 15]
• Display chime zones:
authorises the device to display the open chime zones.
At least one area to which the tamper alarms generated by the device are to be signalled must be assigned to each active device [Reg. 5]
At least one area to which the technical alarms generated by the device are to be signalled must be assigned to each active device [Reg. 6]
SYSTEM STATUS DISPLAY TIME
TAMPER ALARM CYCLES
CONFIGURATIONS PANEL
DISPLAY TAMPER
DISPLAY TECHNICAL ALARMS
OPTIONS
• Unlimited:
allows you to generate infinite cycles of technical alarms. If not selected, enables the Cycles box.
Selected [Reg. 13]
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of technical alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
TECHNICAL ALARMS CYCLES (BUS/VOLTAGE LEVELS)
Column showing the names of the areas in the system. To edit names, see
"3.6 Areas" on page 37
.
Selects the areas of which you want to show the status with the device.
AREA
SHOW
When a valid and authorised RFID key is passed near a device capable of reading it, as well as performing a Total Activation or Total Deactivation
(of the relevant areas), it is possible to activate the system in custom mode (see user manual for keypad Art. VEDOLCDPRO for operating modes
relating to this function).
If this activation procedure is used, the keypad will display the set scenarios cyclically (Max 4) and the user will have to choose which one to activate.
This section of the program can be used to define the scenarios corresponding to the sequential steps of the cycle shown by the keypad display.
There are two drop-down menus for each of the 4 steps in the cycle. The first menu allows you to select only the Scenario / Activation option,
whereas the second menu allows you to choose from several standard configurations or from a series of custom activation scenarios (see
"3.9
Scenarios" on page 42
):
• Scenario P1:
for the areas covered, activates all zones that have a check in the Partial 1 checkbox (if the default settings are maintained).
• Scenario P2:
for the areas covered, activates all zones that have a check in the Partial 2 checkbox (if the default settings are maintained).
• Scenario P1+P2
for the areas covered, activates all zones that have a check in the Partial 1 or Partial 2 checkbox (if the default settings are
maintained).
• Scenario "n" with "n" from 4 to 16:
all activations / deactivations defined in the selected scenario are executed.
• Total Activation:
for the areas covered, activates all zones.
• Total Deactivation:
for the areas covered, deactivates all zones.
PROXIMITY CARD CYCLE ACTIONS (ART. VEDOLCDPRO ONLY)