STATUS/DESCRIPTION PANEL
• Serial number:
the device serial number will appear the moment it is acquired.
• Type:
the type of sensor acquired is shown the moment the radio code of the peripheral is acquired (e.g.: Reed for a contact transmitter or PIR
for a passive infrared detector).
• Acquire:
for starting the code acquiring phase for the zone corresponding to the selected position, by means of the radio expansion module
with which it is associated.
• Delete:
deletes the code of the selected position, making it available again to be associated with a new radio device.
• Radio monitor time (minutes):
allows you to set the time lapse between two consecutive transmissions of the sensor “existence” frame. The
control panel will use these transmissions to assess the presence and correct operating status of the sensor.
In the event of repeated failure to receive these transmissions, the control panel is capable of generating an
anomaly or alarm.
= 20 min [Reg. 35]
• LED enabled:
if selected, enables the LED on the radio sensor.
• Tamper enabled:
if selected, enables the tamper on the radio sensor.
Selected [Reg. 36]
• Enabling APS:
(Automatic Power Saving) if selected, with the system off, allows the reduction of battery consumption (by reducing the number
of communications of the sensors with the radio concentrator).
• Read:
when this key is pressed the radio signal is read. The Minimum RSSI Acquisition value must be 40 RSSI.
RSSI is the power of the radio signal between the sensor in use and the radio transmitter to which it is associated, where 0 is no signal and 100 is
the maximum value that can be obtained.
• Unlimited:
allows you to generate infinite cycles of fault alarms. If not selected, enables the Cycles box.
Selected [Reg. 33]
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of fault alarm cycles that the selected sensor can generate within
an activation cycle (from one activation to the next).
• Gain control:
set the sensitivity value of the PIR from 1 (lowest value) to 4 (highest value).
• Pet immunity:
if selected, activates the Pet Immunity function (to allow the presence of small animals).
• Number of pulses:
allows you to set the number of pulses.
• Switch in AND:
if selected, the alarm will be generated only if both inputs are open.
• External switch:
if selected, the input for the sensor terminal block will be considered to be in use.
• Internal switch:
if selected, the internal input, corresponding to the reed capsule in the sensor, will be considered to be in use.
• Smoke sensor:
if selected, enables the respective sensor.
• Heat sensor:
if selected, enables the respective sensor.
CONFIGURATIONS PANEL
RADIO ZONE PROPERTIES
OPTIONS
RSSI (SIGNAL LEVEL INDICATOR 0-100)
FAULT CYCLES
PIR (OPTIONS APPLY TO PIR SENSORS ONLY)
REED (OPTIONS APPLY TO REED SENSORS ONLY)
SMOKE
See description
Status / ID / Description on page 87
.
Button allowing the configurations of a zone to be copied so as to paste them onto an existing zone.
1. Select the zone of which you want to copy the configurations.
2. Press the icon to copy.
3. Select the zone where you want to paste the configurations from the window "Duplicate current zone on zone..."
4. Confirm.
Uniquely identifies the zone within the framework of the internal numbering of the control panel. Cannot be modified by the installer.
Shows a description of the radio module with which the radio zone is associated.
STATUS / ID / DESCRIPTION
DUPLICATE THE VALUES OF THE CURRENT ZONE...
PHYSICAL ID
SOURCE EXPANSION