61
1
2
3
4
ID Description
Tamper Alarm
No network
Battery low
Telephone 2
Telephone 3
Telephone 4
Smith John
Activation voice message
Reset voice message
Telephone
Generic events
Send activation SMS
Send reset SMS
Send activation email
Send reset email
9
Event 5
Event 6
Event 7
Event 8
Event 9
11
12
Event 11
Event 12
8
5
7
6
10 Event 10
Burglar Alarm
3.12.4 Generic events
This section is for configuring the events that can generate communications/messages to the devices. In practice, the configuration of a generic
event consists of assigning behaviour rules and procedures for contacting the available telephone numbers to each of the forty-eight possible
events.
Button for configuring the Text-to-Speech section by loading the voice to be used for audio transmission. The procedure is described in detail in
the
Free Voice Messages section on page 8.
Checkbox; if selected, enables the transmission of a voice message activating an event.
For all generic events with a configured event (excluding
tests), the sending of an activation voice message must be enabled for at least one phone enabled in the phone book [Reg. 78]
Checkbox; if selected, enables the transmission of a voice message resetting an event.
For all generic events with a configured event (excluding
tests), the sending of a reset voice message must be enabled for at least one phone enabled in the phone book [Reg. 79]
TEXT TO SPEECH CONFIGURATION
ACTIVATION VOICE MESSAGE
RESET VOICE MESSAGE
Numerical box, uniquely identifies the position of the event.
Alphanumeric box, contains a description of the event to which the parameters in the line correspond.
ID
DESCRIPTION
STATUS/DESCRIPTION PANEL
TELEPHONE PANEL
Description identifying the telephone in the contacts list.
Checkbox; if selected, enables the transmission of an SMS activating an event.
Checkbox; if selected, enables the transmission of an SMS resetting an event.
TELEPHONE
SEND ACTIVATION SMS
SEND RESET SMS
Checkbox; if selected, enables the transmission of an email activating an event.
Checkbox; if selected, enables the transmission of an email resetting an event.
SEND ACTIVATION EMAIL
SEND RESET EMAIL
If there is no digital communicator, the following general events must be indicated (transmission of the corresponding voice message must also have
been completed): [Reg. 80]
System/ZoneAlarm/Robbery
System/ZoneAlarm/Burglary
System/ZoneAlarm/H24
System/OR alarm/Sabotage
System/OR alarm/Expansion buses
System/Fault/Control panel ID power supply unit fault
System/Fault/Radio zone battery fault
System/Fault/Siren battery fault
System/Generic/Timed activation error
System/Fault/Failed activation fault
System/Fault/Zone Fault
System/Fault/Robbery Zone Fault
System/Fault/Motion sensor jamming fault
Timer/Timer Events/Timer ON/Regular pstn and email communication
Timer/Timer Events/Timer ON/Regular gsm communication
Содержание VEDO 2.6 Series
Страница 99: ...99...