17
Status
Activate
Absent
Absent
Absent
1
2
3
4
ID Description
Reader 1
Reader 2
Reader 3
Reader 4
Area 2
Area 3
Area 4
Area 5
Area 6
Area 7
Area 8
Area 1
Checked areas
Display tamper
Display technical alarms
Area
Tamper alarm cycles
Unlimited
Cycles
0
Technical alarms cycles (bus / voltage levels)
Unlimited
Cycles
0
Cycle actions
Red LED cycle action
Scenario / Activat
Scenario / Activat
Scenario / Activat
Scenario / Activat
Yellow LED cycle action
Blue LED cycle action
Green LED cycle action
RFID readers
Buzzer
Enabled
Input
Output
Alarm
Chime
Pre-alarm
Pre-alert
Send message options
Send detailed events SMS
Send Email messages
Send digital communication
Send notification to App
Active
Absent
Absent
Absent
5
6
7
8
Reader 5
Reader 6
Reader 7
Reader 8
LED ON time on proximity key
Unlimited
Seconds
0
(+30)
Total activation
Scenario P1
Scenario P2
Scenario P1+P2
Forced activation
Failed activation
Activation/Deactivation executed
3.1.4 RFID readers
In the project there must be no active or isolated RFID readers [Reg. 43]
See description
Status / ID / Description on page 87
.
STATUS / ID / DESCRIPTION
STATUS/DESCRIPTION PANEL
Selects the areas that can be controlled by the device during normal operation.
Column showing the names of the areas in the system. To edit names, see
"3.6 Areas" on page 37
Allows you to choose to which areas the Tamper alarm generated by the device is sent.
AREAS PANEL
CHECKED AREAS
AREA
DISPLAY TAMPER
Allows you to choose to which areas the technical alarms generated by the device are sent.
DISPLAY TECHNICAL ALARMS
CONFIGURATIONS PANEL
• Unlimited:
allows continuous display of the information provided by the 4 reader LEDs. If not selected, enables the Time box. To guarantee
conformity with standards CEI EN 50131-1 and 50131-3, this option must be disabled.
• Seconds:
if the Unlimited checkbox is not active, this box determines the time, in seconds, for which the RFID reader is enabled to show the
information associated to its LEDs, after the presentation of a valid, authorised RFID key. The system will automatically add 30
seconds to the set time.
LED ON TIME ON PROXIMITY KEY
• Unlimited:
allows you to generate infinite cycles of tamper alarms. If not selected, enables the Cycles box.
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of tamper alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
TAMPER ALARM CYCLES
• Unlimited:
allows you to generate infinite cycles of technical alarms. If not selected, enables the Cycles box.
• Cycles:
if the Unlimited checkbox is not active, this box determines the number of technical alarm cycles that the selected device can generate
within an activation cycle (from one activation to the next).
TECHNICAL ALARMS CYCLES (BUS/VOLTAGE LEVELS)
Содержание VEDO 2.6 Series
Страница 99: ...99...