81
5.3.1 Keypads
Vedo10
x: from 1 to 2 /
Vedo34
x: from 1 to 8 /
Vedo68
x: from 1 to 8 /
Vedo200
x: from 1 to 16
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.1.x.2
Checked areas
At least one selected area
1.1.1.1.x.4
Tamper areas
At least one selected area
1.1.1.1.x.5
Technical areas
At least one selected area
1.1.1.1.x.16
Buzzer on
Active
1.1.1.1.x.17
Entrance Buzzer
Active
1.1.1.1.x.18
Exit Buzzer
Active
1.1.1.1.x.19
Alarm Buzzer
Active
1.1.1.1.x.22
Pre-alert Buzzer
Active
1.1.1.1.x.24
System status display time
0 (+30 seconds)
1.1.1.1.x.25
Tamper cycles
Unlimited
1.1.1.1.x.26
Technical cycles
Unlimited
1.1.1.1.x.27
Unlimited System status
display time
Deselected
1.1.1.1.x.28
Unlimited tamper cycles
Selected
1.1.1.1.x.29
Unlimited technical cycles
Selected
1.1.1.1.x.33
Quick activation
Deselected
1.1.1.1.x.35
Area status
Selected
1.1.1.1.x.37
Zones open
Selected
1.1.1.1.x.40
Send email
Selected
1.1.1.1.x.41
Send Digital Com
Selected
1.1.1.1.x.43
Buzzer ActDeact
Selected
1.1.1.1.x.44
Buzzer Act.Failed
Selected
5.3.2 App
x: from 1 to 8
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.5.x.2
Controllable areas
At least one selected area
1.1.1.5.x.3
Tamper areas
At least one selected area
1.1.1.5.x.4
Tamper cycles
Unlimited
1.1.1.5.x.9
Send email
Selected
1.1.1.5.x.10
Send digital communication
Selected
1.1.1.5.x.12
Unlimited tamper cycles
Selected
1.1.1.5.x.23
Unlimited start-up time
Deselected
5.3.3 Input/output expansions (8I8O)
Vedo10
x: not available /
Vedo34
x: from 1 to 8 /
Vedo68
x: from 1 to 12 /
Vedo200
x: from 1 to 50
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.7.x.2
Tamper areas
At least one selected area
1.1.1.7.x.3
Technical areas
At least one selected area
1.1.1.7.x.4
Tamper cycles
Unlimited
1.1.1.7.x.5
Technical cycles
Unlimited
1.1.1.7.x.8
Unlimited tamper cycles
Selected
1.1.1.7.x.9
Unlimited technical cycles
Selected
1.1.1.7.x.11
Send email
Selected
1.1.1.7.x.12
Send Digital Com
Selected
5.3.4 Power supply stations
Vedo10
x: from 1 to 1 /
Vedo34
x: from 1 to 4 /
Vedo68
x: from 1 to 8 /
Vedo200
x: from 1 to 8
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.8.x.2
Tamper Areas
At least one selected area
1.1.1.8.x.3
Technical Areas
At least one selected area
1.1.1.8.x.4
Tamper cycles
Unlimited
1.1.1.8.x.5
Technical cycles
Unlimited
1.1.1.8.x.7
Unlimited tamper cycles
Selected
1.1.1.8.x.8
Unlimited technical cycles
Selected
1.1.1.8.x.10
Send email
Selected
1.1.1.8.x.11
Send digital communications
Selected
1.1.1.8.x.13
Tamper enabled
Selected
1.1.1.8.x.14
Network alarm delay
Max 60 seconds
1.1.1.8.x.15
Battery alarm delay
Max 5 minutes
5.3.5 Isolators
Vedo10
x: from 1 to 4 /
Vedo34
x: from 1 to 8 /
Vedo68
x: from 1 to 16 /
Vedo200
x: from 1 to 16
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.9.x.2
Tamper areas
At least one selected area
1.1.1.9.x.3
Technical areas
At least one selected area
1.1.1.9.x.4
Tamper cycles
Unlimited
1.1.1.9.x.5
Technical cycles
Unlimited
1.1.1.9.x.7
Unlimited tamper cycles
Selected
1.1.1.9.x.8
Unlimited technical cycles
Selected
1.1.1.9.x.10
Send email
Selected
1.1.1.9.x.11
Send digital communications
Selected
1.1.1.9.x.13
Tamper enabled
Selected
5.3.6 Radio expansion
Vedo10
x: from 1 to 1 /
Vedo34
x: from 1 to 2 /
Vedo68
x: from 1 to 3 /
Vedo200
x: from 1 to 8
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.10.x.2
Tamper areas
At least one selected area
1.1.1.10.x.3
Technical areas
At least one selected area
1.1.1.10.x.4
Tamper cycles
Unlimited
1.1.1.10.x.5
Technical cycles
Unlimited
1.1.1.10.x.7
Unlimited tamper cycles
Selected
1.1.1.10.x.8
Unlimited technical cycles
Selected
1.1.1.10.x.10
Send email
Selected
1.1.1.10.x.11
Send digital communication
Selected
5.3.7 Radio outputs
Vedo10
x: from 1 to 16 /
Vedo34
x: from 1 to 32 /
Vedo68
x: from 1 to 48 /
Vedo200
x: from 1 to
128
y:
from 1 to 4
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.11.x.7
Siren on time out (not active)
**
1.1.1.11.x.8
Siren sound for on (not active)
**
1.1.1.11.x.13
Cycle Outputs
**
1.1.1.11.x.14
Unlimited Cycle Outputs
**
1.1.1.11.x.15
Output type
*** Monostable
1.1.1.11.x.17
OFF Time
**
1.1.1.11.x.19
ON Time
**
1.1.1.11.x.20
System status areas
At least one selected area
1.1.1.11.x.21
Tamper and technical areas
At least one selected area
1.1.1.11.x.22
Sabotage cycles
Unlimited
1.1.1.11.x.23
Technical cycles
Unlimited
1.1.1.11.x.24
Monitoring time
Maximum 20 minutes
1.1.1.11.x.25
Unlimited sabotage cycles
Selected
1.1.1.11.x.26
Unlimited technical cycles
Selected
1.1.1.11.x.31
Disable battery check
Deselected
** The total activation time of a siren must not exceed that prescribed by local regulations.
*** These apply only to sirens
RADIO OUTPUT EVENTS
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.11.x.27.y.1
Event
* Alarms/S Motion sensor
jamming fault
1.1.1.11.x.27.y.2
Polarity
* Direct
1.1.1.11.x.27.y.3
And/or
* OR
* These apply only to sirens
RADIO OUTPUT CONFIGURATION
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.11.x.28.1.1
Timer in And
* No timer
1.1.1.11.x.28.1.2
Timer in Or
* No timer
1.1.1.11.x.28.1.7
Events logic
* OR
1.1.1.11.x.28.1.9
Send email
Selected
1.1.1.11.x.28.1.10
Send digital communicator
Selected
1.1.1.11.x.28.1.12
Output activation only with
system activated
Selected if connected to a siren
* These apply only to sirens
5.3.8 Radio controls
Vedo10
x: from 1 to 11 /
Vedo34
x: from 1 to 64 /
Vedo68
x: from 1 to 96 /
Vedo200
x: from 1 to
256
Indices
Parameters
Configurations necessary to guarantee
Grade 2 certification
1.1.1.12.x.3
Areas
At least one selected area
1.1.1.12.x.5
Unlimited fault cycles
Selected
1.1.1.12.x.7
Fault cycles
Unlimited
1.1.1.12.x.13
Send email
Selected
1.1.1.12.x.14
Send digital communications
Selected
1.1.1.12.x.19
Forced activation
Deselected
This chapter provides indications on the configuration parameters which,
if varied, could lower the safety level of the system, and the configurations