18
When a valid and authorised RFID key is passed near an RFID reader, as well as performing a Total Activation or Total Deactivation (of the relevant
areas), it is possible to activate the system in custom mode (see user manual for RFID reader Art. VEDOPROX for operating modes relating to this
function).
If this activation procedure is used, the RFID reader will display the set scenarios cyclically (max. 4) via the LEDs and the user will have to choose
which one to activate.
This section of the program can be used to define the scenarios corresponding to the sequential steps of the cycle shown by the RFID reader LEDs.
There are two drop-down menus for each of the 4 steps in the cycle (identified by the colours of the 4 LEDs on the RFID reader). The first menu
allows you to select only the Scenario / Activation option, whereas the second menu allows you to choose from several standard configurations or
from a series of custom activation scenarios (see
"3.9 Scenarios" on page 42
):
• Scenario P1:
for the areas covered, activates all zones that have a check in the Partial 1 checkbox (if the default settings are maintained).
• Scenario P2:
for the areas covered, activates all zones that have a check in the Partial 2 checkbox (if the default settings are maintained).
• Scenario P1+P2:
for the areas covered, activates all zones that have a check in the Partial 1 or Partial 2 checkbox (if the default settings are
maintained).
• Scenario "n" with "n" from 4 to 16:
all activations / deactivations defined in the selected scenario are executed.
• Total Activation:
for the areas covered, activates all zones.
• Total Deactivation:
for the areas covered, deactivates all zones.
CYCLE ACTIONS
See description
Buzzer on page 88
.
When the function is enabled, the RFID reader will always carry out activation, forcing the activation lock conditions.
(*) Indications relating to LED ON status have priority over any other indications (flashing) that may be present with the exception of the alarm
memory, Flashing Red, which takes priority over Red LED ON.
(*) The purpose of forcing is to overcome a 'not ready' condition in one or more of the zones associated with the areas covered by the reader, and/
or an anomaly which can be overridden due to the choices made at the time of control panel configuration.
MEANING OF READER LEDS IN NORMAL CONDITIONS
RED
YELLOW
BLUE
GREEN
OFF
All areas covered by the reader are deactivated. There are no saved alarms relating to the areas.
ON
The activation profile associated
with the RED LED (*) is active
The activation profile associated
with the YELLOW LED (*) is active
The activation profile associated
with the BLUE LED (*) is active
The activation profile associated
with the GREEN LED (*) is active
FLASHING SLOWLY
All areas covered by the reader are
deactivated. There is an area alarm
or sabotage memory, or a control
panel sabotage memory.
System activated with unknown
scenario (not saved).
FLASHING QUICKLY
At least one of the areas covered
by the reader is activated. There
is an area alarm or sabotage
memory, or a control panel
sabotage memory.
One or more anomalies have been
detected in the areas covered by
the reader and/or there is a system
fault.
At least one area covered by the
reader is not ready for activation.
MEANING OF READER LEDS DURING PRESENTATION OF THE KEY
RED
YELLOW
BLUE
GREEN
OFF
Request for deactivation of all areas covered by the reader.
ON
Request for activation of the
activation profile associated with
the RED LED
Request for activation of the
activation profile associated with
the YELLOW LED
Request for activation of the
activation profile associated with
the BLUE LED
Request for activation of the
activation profile associated with
the GREEN LED
FLASHING QUICKLY
The reader is forcing the activation
profile associated with the RED
LED (*)
The reader is forcing the activation
profile associated with the
YELLOW LED (*)
The reader is forcing the activation
profile associated with the BLUE
LED (*)
The reader is forcing the activation
profile associated with the
GREEN LED (*)
See description
Send Message options on page. 89
.
BUZZER
FORCED ACTIVATION
SEND MESSAGE OPTIONS
Содержание VEDO 2.6 Series
Страница 99: ...99...