InteliMains 210 Global Guide
206
Setpoint group
Synchronisation
Related FW
2.0.0
Range [units]
0,01 .. 0,50 [Hz]
Default value
0,15 Hz
Alternative config
NO
Step
0,01 Hz
Comm object
14799
Related applications
MCB, MGCB, BTB
Description
Window of slip frequency for slip synchronization (
Synchronization Type (page 204)
= Slip Synchro).
Slip Frequency Window
Setpoint group
Synchronisation
Related FW
2.0.0
Range [units]
20 .. 1 000 [ms]
Default value
80 ms
Alternative config
NO
Step
1 ms
Comm object
14800
Related applications
MCB, MGCB, BTB
Description
Latency of MGCB.
IMPORTANT: This setpoint is enable, when
Synchronization Type (page 204)
has Split Synchro
value
MGCB Latency
Setpoint group
Synchronisation
Related FW
2.0.0
Range [units]
20 .. 1 000 [ms]
Default value
80 ms
Alternative config
NO
Step
1 ms
Comm object
14801
Related applications
MCB, MGCB, BTB
Description
Latency of MCB.
IMPORTANT: This setpoint is enable, when
Synchronization Type (page 204)
has Split Synchro
value
MCB Latency