Warning: a clearance must be left behind the appliance for the electric cables and the drain pipe. The drain
pipe must not have upward siphoning. This condition could in fact compromise the correct water flow.
Diagram for the installation of the W60-W45-W30 models in a column unit.
W60 –W45
W30
Measurements are in mm.
Ensure that there is enough room for opening the door. Consider the condensation drain and the spaces
underneath for the passage of the drain pipe.
Warning: for correct air recirculation, ensure that the rear upper wall of the unit is open for ventilation, with a
minimum air opening of 280 cm2 (see figure). For W30 free-standing appliances allow a clearance of 30 mm
from the wall for air recirculation.
Warning: for correct air recirculation, ensure that the rear upper wall of the unit is open, with a
minimum air opening of 280 cm2 (see figure). For W30 free-standing appliances allow a clearance
of 30 mm from the wall for air recirculation. Also ensure that the ventilation grid at the bottom is
free, to allow the passage of air.
3.9
DRAIN CONNECTION
Connect the clear drain pipe supplied to the copper tube as indicated by the arrow on the figure and secure
with two clips.
Содержание W30
Страница 2: ......
Страница 84: ...84 Русский Eespañol Italiano English Deutsch Français Nederlands ...
Страница 112: ...112 Русский Eespañol Italiano English Deutsch Français Nederlands ...
Страница 140: ...140 Русский Eespañol Italiano English Deutsch Français Nederlands ...
Страница 193: ......
Страница 194: ......
Страница 195: ......