BATTERIES
Battery Care
Page 14-6
2008-2011 IQ Plus Electric Vehicle Maintenance and Service Supplement
14
per million and their impact on battery performance. Your local water company should be able to perform test-
ing and compare their results to the chart.
If using tap water, Club Car's Service Parts Department offers two different deionizer systems: one for vehi-
cles equipped with the Single Point Water System (SPWS) P/N AM1240701 and the other for vehicles without
SPWS, P/N AM10974.
Mineral Content
For the longest battery life, use distilled water in batteries. However, if other water is to be used, be sure the
mineral contents are below these levels:
VIBRATION DAMAGE
The battery hold-downs should always be tight enough to keep the battery from bouncing. Battery life may be
severely shortened if the battery hold-downs are too loose. Battery hold-downs should be tightened to 40 in-
lb (4.5 N·m). Excessive vibration causes the plates to shed prematurely and shortens the life of the battery. It
may also cause acid to leak out of the vent caps and corrosion to build up on surrounding metal parts. The
acid which is lost reduces the capacity of the battery and cannot be replaced. Battery hold-downs should NOT
be so tight as to crack or buckle the battery case. This may cause leaks which would dry out a cell or cause
internal short circuits.
See Battery Replacement on page 14-2.
IMPURITY
ALLOWABLE CONTENT
(PARTS PER MILLION)
EFFECTS OF IMPURITY
Suspended matter
Trace
–
Total solids
100.0
–
Calcium
40.0
Increase of positive shedding
Magnesium
40.0
Reduced life
Iron
3.0
Increased self-discharge at both plates, lower on-
charge voltage
Ammonia
8.0
Slight self-discharge of both plates
Organic and volatile matter
50.0
Corrosion of positive plate
Nitrates
10.0
Increased sulfation at negative
Nitrites
5.0
Corrosion at both plates, loss of capacity, reduced life
Chloride
5.0
Loss of capacity in both plates, greater loss in positive
Color
Clear and “White”
–
Antimony
5.0
Self-discharge by local action, reduces life, lower on-
charge voltage
Arsenic
0.5
Self-discharge, can form poisonous gas at negative
Copper
5.0
Increased self-discharge, lower oncharge voltage
Nickel
None Allowed
Intense lowering of on-charge voltage
Platinum
None Allowed
Violent self-discharge, lower on-charge voltage
Selenium
2.0
Positive shedding
Zinc
4.0
Slight self-discharge at negative
Содержание IQ PLUS 2008
Страница 2: ......
Страница 62: ...11...
Страница 102: ...13...
Страница 118: ...14...
Страница 120: ...15...
Страница 136: ...16...
Страница 148: ...17...
Страница 154: ...18...
Страница 158: ......
Страница 160: ......
Страница 161: ...Club Car R NOTES...
Страница 162: ...Club Car R NOTES...
Страница 163: ......