MOTOR (MODEL DA5-4006)
Motor Component Testing and Inspection
Page 16-8
2008-2011 IQ Plus Electric Vehicle Maintenance and Service Supplement
16
4.1. Place a C-shaped steel plate on a scale.
4.2. Place the end of the C-shaped plate so that it is between the spring and the brush.
4.3. Gently pull the scale to obtain the spring tension reading.
See following CAUTION.
CAUT ION
• When checking brush spring tension, do not over-extend the spring. Using excessive force
will damage the spring.
4.4. Replace springs which require a force of less than 35 oz. (990 grams)
See following NOTE.
NOTE:
When installing new brushes, remove and replace brushes one at a time. This method ensures the
terminals and brushes will be properly positioned in the rigging. Refer to Motor Assembly for brush
installation.
See Motor Assembly on page 16-11.
When replacing brushes, replace all four brushes. Never replace only two.
Install the brushes in the same rigging 180° apart from each other.
Brush Inspection
1. Remove the motor from the vehicle.
See Motor Removal, Section 16, Page 16-2.
2. Release the clasp and remove the headband from the motor.
3. Inspect the brushes (16) for damage or excessive wear
. Replace brushes
if required.
See preceding NOTE.
4. Use dial calipers or a micrometer to measure the brush length. The minimum allowable brush length is
0.62 inches (16 mm). Replace the set of brushes as required.
See preceding NOTE.
Содержание IQ PLUS 2008
Страница 2: ......
Страница 62: ...11...
Страница 102: ...13...
Страница 118: ...14...
Страница 120: ...15...
Страница 136: ...16...
Страница 148: ...17...
Страница 154: ...18...
Страница 158: ......
Страница 160: ......
Страница 161: ...Club Car R NOTES...
Страница 162: ...Club Car R NOTES...
Страница 163: ......