ELECTRICAL SYSTEM TROUBLESHOOTING: IQ
PLUS ELECTRIC VEHICLES
Test Procedures
12
TEST PROCEDURE 2 – 48-Volt Battery Pack Voltage Under Load
See General Warnings on page 1-1.
NOTE:
This is a voltage test.
1.
If necessary, see Testing Basics on page 12-14.
2.
Be sure the batteries are fully charged and that the electrolyte level is correct in all cells.
3.
Connect the tester leads to the positive (+) post of battery no.1 and negative (–) post of battery no. 8
(Viewed from driver side of vehicle)
1. RED probe to battery no. 1 (+).
2. BLACK probe to battery no. 8 (-).
2780a
Figure 12-6
Battery Discharge Test
TES
TER
(Viewed from driver side of vehicle)
1. RED probe to battery no. 1 (+).
2. BLACK probe to battery no. 8 (-).
2781a
Figure 12-7
Battery Discharge Test
4.
Turn the discharge machine on and record the voltage reading of battery pack while under load.
2017 Carryall 500 and 700 Maintenance and Service Manual
Page 12-17