Procedure
Step 1
Place the right front air deflector flush against the right side of the chassis as shown in Diagram 1 of
Step 2
Align the screw holes on the right front air deflector with the screw holes on right side of the chassis.
Step 3
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m). See Diagram 2 of
Step 4
Place the left back air deflector flush against the chassis as shown in Diagram 1 of
Air Deflectors (Front-to-Back) on the ONS 15454 M2 Shelf for ANSI Rack Configuration, on page 201
.
If the 100G-LC-C, 10x10G-LC, or CFP-LC cards are to be installed in the ONS 15454 M2 shelf,
do not mount the left back deflector (exhaust air deflector). Use the standard brackets directly to
mount the ONS 15454 M2 shelf.
Note
Step 5
Align the screw holes on the left back air deflector with the screw holes on the chassis.
Step 6
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m). See Diagram 2 of
Step 7
Place the air deflector covers on the front and rear ends of the chassis as shown in Diagram 3 of
Step 8
Align the screw holes on the air deflector covers with the screw holes on the chassis.
Step 9
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m). See Diagram 4 of
Step 10
Place the 23-inch mounting bracket flush in the front position (see Diagram 1 of
Brackets on the ONS 15454 M2 Shelf for ANSI Rack Configuration, on page 201
) or in the middle position
(see Diagram 3 of
Figure 124: Mounting the Brackets on the ONS 15454 M2 Shelf for ANSI Rack
) against the right side of the chassis.
Step 11
Align the screw holes on the 23-inch mounting bracket with the screw holes on the right side of the chassis.
Step 12
Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m).
Cisco ONS 15454 Hardware Installation Guide
200
Installing the ONS 15454 M2 Shelf
DLP-G584 Mounting the Bracket with Air Deflectors (Front-to-Back) on the ONS 15454 M2 Shelf for ANSI Rack Configuration
Содержание ONS 15454
Страница 2: ... 2019 Cisco Systems Inc All rights reserved ...
Страница 16: ...Cisco ONS 15454 Hardware Installation Guide xvi Contents ...
Страница 28: ...Cisco ONS 15454 Hardware Installation Guide xxviii Preface Preface ...
Страница 36: ...Cisco ONS 15454 Hardware Installation Guide 6 Overview Cisco ONS 15454 M6 Shelf ...
Страница 510: ...Cisco ONS 15454 Hardware Installation Guide 480 Hardware Specifications Dimensions ...