NTP-G15 Install the Common Control Cards, on page 131
DLP-G371 Install the Ethernet Adapter Panel, on page 126
(Optional) “DLP-G264 Enable Node Security Mode” in “Turn Up a Node” chapter
of the Cisco ONS 15454 DWDM Configuration Guide.
Prerequisite Procedures
As needed
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Procedure
Step 1
To connect the MS-ISC-100T cards to the node controller shelf and set up protection, complete the following
substeps (see
Figure 65: Connecting the EAP to the Node Controller and Subtending Shelf, on page 140
). For
more information on MS-ISC-100T card port assignments, refer to the “Install the Control Cards” chapter in
the Cisco ONS 15454 DWDM Configuration Guide.
a) Using the 5.9 in. (0.15 m) CAT-5 LAN cable, plug one connector into the NC port of the MS-ISC-100T
card located on the left side of the node controller shelf (Slots 1 to 6) and plug the other connector into
the front panel (RJ-45 connector) of the TCC2/TCC2P/TCC3 card in Slot 7.
b) Using the 5.9 in. (0.15 m) CAT-5 LAN cable, plug one connector into the NC port of the MS-ISC-100T
card located on the right side of the node controller shelf (Slots 12 to 17) and the other end into the front
panel (RJ-45 connector) of the TCC2/TCC2P/TCC3 card in Slot 11.
c) Using the 19.69 in. (0.5 m) CAT-5 LAN cable, plug one connector into the PRT port of the MS-ISC-100T
card located on the left side of the node controller shelf (Slots 1 to 6) and plug the other connector into
the PRT port of the MS-ISC-100T card located on the right side of the node controller shelf (Slots 12 to
17).
d) Plug the nine connectors on one end of the EAP cable into the two DCN ports and the seven subtending
shelf controller (SSC) ports of the MS-ISC-100T card located on the left side of the node controller shelf
(Slots 1 to 6). Plug the other end of the EAP cable into the multishelf port on the left EAP.
e) Plug the nine connectors on one end of the EAP cable into the two DCN ports and the seven SSC ports
of the MS-ISC-100T card in the right side of the NC shelf (Slots 12 to 17). Plug the other end of the EAP
cable into the multishelf port on the right EAP.
Cisco ONS 15454 Hardware Installation Guide
139
Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
NTP-G301 Connect the ONS 15454 Multishelf Node and Subtending Shelves to an MS-ISC-100T Card
Содержание ONS 15454
Страница 2: ... 2019 Cisco Systems Inc All rights reserved ...
Страница 16: ...Cisco ONS 15454 Hardware Installation Guide xvi Contents ...
Страница 28: ...Cisco ONS 15454 Hardware Installation Guide xxviii Preface Preface ...
Страница 36: ...Cisco ONS 15454 Hardware Installation Guide 6 Overview Cisco ONS 15454 M6 Shelf ...
Страница 510: ...Cisco ONS 15454 Hardware Installation Guide 480 Hardware Specifications Dimensions ...